Products
Downloads Login
DX 90B Linear Motor

- Ironless Motor
- Peak force to 3625N, Continuous force to 1812N
- Integrated with Hall Sensor
- Ideal for high precision/smooth motion
Specifications
Performance
|
MOTOR MODEL |
DX90B-C2 |
DX90B-C3 |
DX90B-C4 |
DX90B-C6 |
DX90B-C8 |
DX90B-C10 |
|
|
Peak Force |
N |
725 |
1088 |
1450 |
2175 |
2900 |
3625 |
|
Continuous Force1 |
N |
181 |
272 |
363 |
544 |
725 |
906 |
|
Continuous Force AC2 |
N |
253.4 |
380.8 |
508.2 |
761.6 |
1015 |
1268.4 |
|
Continuous Force WC3 |
N |
362 |
544 |
726 |
1088 |
1450 |
1812 |
|
Peak Power |
W |
1209.2 |
1813.7 |
2418.3 |
3627.5 |
4836.6 |
6045.8 |
|
Continuous Power1 |
W |
75.6 |
113.4 |
151.1 |
226.7 |
302.3 |
377.9 |
|
Continuous Power AC2 |
W |
148.1 |
222.2 |
296.1 |
444.3 |
592.5 |
740.6 |
|
Continuous Power WC3 |
W |
302.4 |
453.6 |
604.4 |
906.8 |
1209.2 |
1511.6 |
Electrical
|
MOTOR MODEL |
DX90B-C2 |
DX90B-C3 |
DX90B-C4 |
DX90B-C6 |
DX90B-C8 |
DX90B-C10 |
|||||||
|
WIRING TYPE UNITS |
S |
P |
S |
P |
S |
P |
S |
P |
S |
P |
S |
P |
|
|
Peak Current |
A pk |
12.8 |
25.6 |
12.8 |
25.6 |
12.8 |
25.6 |
12.8 |
25.6 |
12.8 |
25.6 |
12.8 |
25.6 |
|
Continuous Current1 |
A pk |
3.2 |
6.4 |
3.2 |
6.4 |
3.2 |
6.4 |
3.2 |
6.4 |
3.2 |
6.4 |
3.2 |
6.4 |
|
Continuous Current AC2 |
A pk |
4.4 |
8.9 |
4.4 |
8.9 |
4.4 |
8.9 |
4.4 |
8.9 |
4.4 |
8.9 |
4.4 |
8.9 |
|
Continuous Current WC3 |
A pk |
6.4 |
12.8 |
6.4 |
12.8 |
6.4 |
12.8 |
6.4 |
12.8 |
6.4 |
12.8 |
6.4 |
12.8 |
|
Force Constant |
N/Apk |
56.7 |
28.3 |
85.0 |
42.5 |
113.3 |
56.7 |
169.9 |
85.0 |
226.6 |
113.3 |
283.2 |
141.6 |
|
Back EMF |
V/ms-1 |
65.4 |
32.7 |
98.1 |
49.1 |
130.8 |
65.4 |
196.2 |
98.1 |
261.6 |
130.8 |
327.1 |
163.5 |
|
Resistance 25°C |
ohms |
7.6 |
1.9 |
11.4 |
2.9 |
15.2 |
3.8 |
22.8 |
5.7 |
30.4 |
9.6 |
38.0 |
9.5 |
|
Inductance |
mH |
9.0 |
2.3 |
13.5 |
3.4 |
18.0 |
4.5 |
27.0 |
6.8 |
36 |
9.0 |
45.0 |
11.25 |
|
Motor Constant |
N/√W |
20.9 |
20.9 |
25.5 |
25.5 |
29.5 |
29.5 |
36.1 |
36.1 |
41.7 |
41.7 |
46.6 |
46.6 |
|
Max. Terminal Voltage |
VDC |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
Wiring Type: S-Series P-Parallel
Thermal
|
MOTOR MODEL |
DX90B-C2 |
DX90B-C3 |
DX90B-C4 |
DX90B-C6 |
DX90B-C8 |
DX90B-C10 |
|
|
Thermal Resistance 1 |
°C / W |
1.3 |
0.9 |
0.7 |
0.4 |
0.3 |
0.3 |
|
Thermal Resistance AC2 |
°C / W |
0.6 |
0.4 |
0.3 |
0.2 |
0.1 |
0.1 |
|
Thermal Resistance WC3 |
°C / W |
0.3 |
0.2 |
0.1 |
0.1 |
0.07 |
0.07 |
|
Max. Winding Temperature |
°C |
120 |
120 |
120 |
120 |
120 |
120 |
Mechanical
|
MOTOR MODEL |
DX90B-C2 |
DX90B-C3 |
DX90B-C4 |
DX90B-C6 |
DX90B-C8 |
DX90B-C10 |
|
|
Coil Weight |
kg |
1.30 |
1.95 |
2.60 |
3.90 |
5.17 |
6.46 |
|
Coil Length |
mm |
121 |
181 |
241 |
361 |
481 |
601 |
|
Attractive Force |
N |
0 |
0 |
0 |
0 |
0 |
0 |
|
Electrical Cycle Length |
mm |
60 |
60 |
60 |
60 |
60 |
60 |
Additional Notes:
· Standard cable length 2 meters.
· 1 Motor coil is thermally insulated from mounting bracket. Ambient temperature. Coil @ 125°C.
· 2 Motor coil is thermally insulated from mounting bracket. Air cooled @ 20psi
· 3 Motor coil is thermally insulated from mounting bracket. Water cooled @ 20°C
Note: specifications are subject to change without prior notice
Drawings
DX90B Standard Magnet Track
|
SIZE |
TRACK LENGTH TL (mm) |
WEIGHT (kg) |
MOUNT HOLE A (ea) |
MOUNT HOLE B (ea) |
|
TL 240 |
239.5 |
8.50 |
4 |
4 |
|
TL 300 |
299.5 |
10.50 |
5 |
5 |
|
TL 360 |
359.5 |
12.50 |
6 |
6 |
|
TL 600 |
599.5 |
21.00 |
10 |
10 |
|
TL 900 |
899.5 |
31.50 |
15 |
15 |
TRACK WEIGHT = 2.1kg PER 60mm.
DX90B Motor Coil
|
SIZE |
COIL LENGTH CL (mm) |
WEIGHT (kg) |
MOUNT HOLE D (ea) |
|
C2 |
121.0 |
2.1 |
4 |
|
C3 |
181.0 |
3.27 |
6 |
|
C4 |
241.0 |
4.35 |
8 |
|
C6 |
361.0 |
6.51 |
12 |
|
C8 |
481.0 |
8.67 |
16 |
|
C10 |
601.0 |
10.83 |
20 |
For COOLING OPTIONS, please ask for detail drawing.
Note: specifications are subject to change without prior notice
Part Numbering System
Coil Assembly
DX50B – C4 – P – TM – 2.0 – A – FC
|
|
|
|
|
|
|
Remarks:
· TM – On/Off switch
· TC – With a simple temperature controller (e.g. Omron), user can read the temperature all the time on a display. User can also set a temperature in the controller to trigger an output
Magnet Track
DX50B – TL300 – K2
|
|
|
Remarks:
· Track length in incremental of 60mm
Note: specifications are subject to change without prior notice