Makes A Difference

IX 90 Iron Core Linear Motor

  • Iron Core Motor
  • Peak force to 1650N, Continuous force to 550N
  • Integrated with Hall Sensor (Optional)
  • Ideal for high force

Specifications

Performance

MOTOR MODEL


IX90-275

IX90-550

Peak Force

N

825

1650

Continuous Force

N

275

550

Electrical Cycle Length

Mm

48

48

Electrical

MOTOR MODEL


IX90-275

IX90-550


WIRING TYPE

UNITS

P

S

P

S

Peak Current

Arms

18.38

6.84

39.2

14.59

Continuous Current

Arms

4.6

1.71

9.8

3.65

Force Constant

N/Arms

60

161

56

151

Phase-to-Phase Resistance 20°C

Ohms

2.1

12.9

0.98

7.21

Phase-to-Phase Inductance

Mh

33.2

235.4

18.2

131.4

Electrical Time Constant

msec

15.8

15.8

18.22

18.22

Power Loss

W

86.8

86.8

191.5

191.5

Motor Constant

N/√W

33.8

33.8

45.6

45.6

Thermal

MOTOR MODEL


IX90-275

IX90-550

Thermal Resistance

°C / W

0.921

0.418

Type Of Thermal Cut-off


NC

NC

Rated Voltage

Vac

250

250

Rated Current

A

2.5

2.5

Operating Temperature

°C

130

130

Resetting Temperature

°C

100 ±15

100 ±15

Reaction Time

ms

1

1

Mechanical

MOTOR MODEL


IX90-275

IX90-550

Coil Weight

Kg

3

7

Coil Length

mm

186

354

Attractive Force

N

1202

2405

Motor Speed

MOTOR MODEL


IX90-275

IX90-550



P

S

P

S

Servo Drive 220V (ac) 3 phase

m/s

4.5

1.5

4.5

1.5

Servo Drive 380V (ac) 3 phase

m/s

>5

3

>5

3

Additional Notes:

· Standard cable length 0.5 meters.

 

Note: specifications are subject to change without prior notice

 

Drawings


Note: specifications are subject to change without prior notice

IX90 Standard Magnet Track

 

TYPE

L (mm)

WEIGHT (kg)

TL120

120

1.1

TL240

240

2.2

TL480

480

4.4

TRACK WEIGHT = 9.1kg PER m.

IX90 Motor Coil

TYPE

COIL LENGTH CL (mm)

WEIGHT (kg)

IX90-275

186

3.0

IX90-550

354

7.0

For COOLING OPTIONS, please ask for detail drawing.

 

Note: specifications are subject to change without prior notice

Part Numbering System

Coil Assembly


 

IX5040P0.5

Motor Model

IX50

IX60

IX90

IX120

IX140

IX170

IX200

Continuous

Force

40

75

275

660

1200

:

Motor Connection

S

P

Cable Length

0.5 m

2.0 m

5.0 m­­

Remarks:

· Motor coils come with embedded HALL SENSORS

· Motor coils come with embedded TEMPERATURE SENSOR


Magnet Track

IX50TL240

Motor Model

IX50

IX60

IX90

IX120

IX140

IX170

IX200

Magnet Track Length

TL120 - 120mm

TL240 - 240mm

TL480 - 480mm

 

Note: specifications are subject to change without prior notice